German French Italian Portuguese Japanese Korrean Russian
Home

News

What should I pay attention to when cleaning the liquid tank of the disassembled liquid tank FFU?

What should I pay attention to when cleaning the liquid tank of the disassembled liquid tank FFU?

In addition to the preparation and operation steps mentioned in the above answer, there are the following precautions when cleaning the liquid tank of the disconnecting liquid tank FFU:
Safety aspect
Wear protective equipment: Wear protective gloves and goggles during operation to prevent detergent or other substances from touching the skin and eyes.
Prevent electric shock and mechanical damage: During the cleaning process, do not touch the electrical parts of the FFU to avoid electric shock. At the same time, be careful to avoid being scratched by the metal edges or parts of the FFU.
Cleaning materials and methods
Use suitable cleaners: Mild and neutral cleaners should be used, and strong acids, alkalis or corrosive cleaners should be avoided to prevent damage to the liquid tank and other parts of the FFU.
Avoid excessive cleaning: do not use too much force or sharp tools when cleaning, so as not to scratch the surface of the liquid tank, affecting its sealing performance and service life.
Thorough rinse: After wiping with the cleaning agent, be sure to thoroughly flush the liquid tank with deionized water to ensure that the residue of the cleaning agent is completely removed to prevent the residual cleaning agent from polluting the filter or the air.
Drying treatment: After cleaning to ensure that the liquid tank is completely dry, you can use a clean soft cloth to dry or natural air dry, avoid the use of heat source forced drying, to prevent damage to the liquid tank or cause deformation.
Installation and commissioning
Correct installation of the filter: When cleaning and installing the filter, operate according to the instructions to ensure that the filter is installed in place and sealed with the liquid tank to avoid gaps or unstable installation.
Commissioning: After the installation is complete, switch on the power supply for commissioning and check the running status of the FFU, including the fan speed, air discharge, liquid tank seal is good, etc. If there is any abnormality, stop the machine in time to check and troubleshoot the fault.