What details do I need to pay attention to when using xenon light transfer Windows?
What details do I need to pay attention to when using xenon light transfer Windows?When using xenon light transfer Windows daily, there are the following details to pay attention to:Before use Check the equipment: check the transfer window for damage, whether the door seal is good, and observe the window for stains or cracks. At the same time, check whether the xenon light source can be opened normally, whether the light intensity is uniform, and if there is an anomaly, it should be repaired or replaced in time. Cleaning and disinfection: the interior of the transfer window should be cleaned and disinfected before use. You can wipe the chamber wall, door handle, and other parts with 75% alcohol, and then turn on the xenon light source for pre-disinfection to ensure that the internal environment of the transfer window meets the health requirements. In use Correct placement of items: The items to be transferred are neatly placed in the transfer window to avoid blocking the xenon light source and air outlet, and ensure that the items can be fully exposed to light disinfection. At the same time, be careful not to let the item be too heavy or too large, so as not to affect the normal closure and sealing of the transfer window door. Avoid frequent opening: In the disinfection process, the number of openings of the transmission window door should be minimized to prevent the outside air from entering the polluting the internal environment, but also to avoid affecting the disinfection effect and increasing the loss of the light source. Observe the operating status: When the xenon light transfer window is working, pay attention to the working status of the light source through the observation window, such as whether there are abnormal conditions such as flickering and extinguishing. If there is any abnormality, it should be stopped immediately and checked and repaired. After use Clean again: After use, remove the delivered items in time, and then clean the interior of the transfer window to remove possible residual stains and debris. You can wipe it with a clean damp cloth and then dry it with a dry cloth to keep the inside dry. Power off: After confirming that nothing is left in the transfer window, turn off the xenon light source and power to save energy and extend the service life of the device. Record usage: Make use of records, including use time, disinfection items, light source operation, etc., to facilitate regular maintenance and troubleshooting. If there is any abnormal situation, it should be recorded in detail to provide a reference for maintenance personnel. |