     Stainless steel windows are auxiliary equipment in cleanrooms, mainly used in clean areas and clean areas. Between the no-clean area and the clean area, reduce the number of cleanroom door openings and minimize clean area contamination.
Use of conveyor windows.
     1. The transfer window is managed according to the higher level clean area connected to it, e.g. the transfer window connecting the coding room and the filling room is managed according to the requirements of the filling room. At the end of the work, the clean area operator should wipe all surfaces inside the transfer window and turn on the ultraviolet germicidal lamp for 30 minutes.1. The transfer window should be kept closed during the use of the two doors with the electrical lighting system of the delivery window, firstly, insert the power plug and connect the power supply of 220V/50Hz.
     2. Need to transfer the items in the window, and do disinfection and sterilization treatment, you can open the power switch of the ultraviolet sterilization lamp, at this time the ultraviolet sterilization lamp lights up, and disinfection and sterilization treatment by the regulations.
     3. In the use of electronic interlocking stainless steel transfer window, open the door of one side of the transfer window, then the other side of the door is automatically locked, so in the delivery of goods, first open the door of the transfer window, the need to pass the items in the transfer window, and then close the stainless steel door of the transfer window, in the sterilization process, the other side of the transfer window door will be opened. The stainless steel door should be closed immediately after the same employee removes the transported item to avoid affecting the transfer of the next item.
Matters to be noted when using the transfer window:
     1. Clean the internal hygiene of the transfer window frequently and replace the UV lamp regularly.
     2. When the material is conveyed from a non-clean area to a clean area, the surface of the material should be cleaned first.
     3. when the interlocking device of the transfer window fails, it should be repaired in time, otherwise, it shall not be used.
Transfer window characteristics.
     1. Mechanical interlocking or electronic interlocking device with reliable performance;
     2. The materials are divided into ① the outer wall is cold plate white plastic spraying, the inner wall and the top plate with stainless steel; ② the box material all adopt 304 stainless steel;
     3. Transmission window optional ultraviolet germicidal lamp. Intercom. Roller.