Troubleshooting methods for air supply ceilings

Troubleshooting methods for air supply ceilings

The following are some troubleshooting methods for common air supply ceiling faults:
I. Insufficient air volume
1. Check the filter
- Check whether the filter is blocked. If blocked, clean or replace it.
- Confirm whether the filter is installed correctly and whether it is loose or misplaced.
2. Check the fan
- Check whether the fan is operating normally and whether there is abnormal noise or vibration.
- Measure the speed of the fan to see if it meets the design requirements.
3. Air duct inspection
- Check whether the air duct has air leakage or blockage.
- Check whether there are foreign objects in the air duct that hinder the airflow.
II. Uneven airflow
1. Check the air outlet of the air supply ceiling
- Observe whether the air outlet is blocked or deformed.
- Confirm whether the layout of the air outlet is uniform.
2. Check the static pressure box
- Check whether the pressure distribution in the static pressure box is uniform.
- Check whether the static pressure box has leakage.
3. Adjust the air valve
- Check whether the opening of the air valve is consistent and adjust the inconsistent air valve.
3. Abnormal temperature
1. Check the air conditioning system
- Confirm whether the air conditioning cooling or heating system is working properly.
- Check the flow and temperature of the refrigerant or heat medium.
2. Sensor detection
- Check whether the temperature sensor is normal and whether the temperature information is accurately fed back.
4. Excessive noise
1. Fan troubleshooting
- Check whether the fan impeller is balanced and whether there is wear or damage.
- Check whether the fan bearing is well lubricated and whether it needs to be lubricated or replaced.
2. Loose component inspection
- Check whether the various components of the air supply ceiling are firmly connected and whether there is looseness that causes vibration and noise.
3. Duct resonance
- Observe whether there is resonance in the duct, and if necessary, add support or change the duct structure.
5. Electrical failure
1. Power supply check
- Confirm whether the power supply is normal and the voltage is stable.
- Check whether the power cord is damaged or short-circuited.
2. Control circuit
- Check whether the control circuit board is faulty and whether the components are damaged.
- Check whether the controller is set correctly.
VI. Odor problem
1. Check the filter
- If the filter is not replaced for a long time, bacteria may breed and produce odor. Replace the filter in time.
2. Clean the air duct
- Dust and dirt accumulated in the air duct may produce odor. Clean the air duct.
3. Check the surrounding environment
- Confirm whether there is a source of odor in the surrounding area that affects the air supply ceiling.
In short, for troubleshooting of air supply ceiling, it is necessary to consider various factors comprehensively, use appropriate tools and methods, gradually find out the cause of the fault, and repair it. For example, the air supply ceiling of a clean workshop had a problem of insufficient air volume. After investigation, it was found that the filter was seriously blocked. After replacing the filter, it returned to normal.