German French Italian Portuguese Japanese Korrean Russian
Home

News

The air shower room is prone to failure and how to solve?

The air shower room is prone to failure and how to solve?

An air shower room is a necessary device leading to a purified clean room. When using an air shower room, there are often malfunctions that may lead to a decrease in the cleanliness of the cleanroom room, thus affecting the safety and success of the production. Therefore, when using an air shower room, we need to understand and master some common troubleshooting methods of air shower rooms.
 
A common air shower room failure is noisy air shower room operation. This problem may be related to the motor or gears. The solution is to switch off the machine and clean the gears or other related parts of the air shower room. If parts need to be replaced or more detailed repairs are made, a professional should be called in. You can turn off the air shower room in one of three ways:

1. The power switch on the outer cabinet
 
2. The control panel on the inner cabinet of the air shower room
 
3. Emergency stop switch on the box of the air shower room.
 
It is also a common problem for air shower doors to fail to close. This can be due to the door swivel being a bit rusty or damaged. To fix this problem, you need to first check if the door hinges are working properly. If the shaft is worn or rusted, it should be replaced immediately.

The problem is that the air shower has very little air velocity. This could be a clogged air filter. In this case, the air shower filters and the condition of each filter should be checked. If the filters are outdated or damaged, they should be replaced promptly. To avoid this, the filters should be inspected and replaced regularly.
 
A common malfunction is that the air shower room does not automatically sense the blowing shower. When the wind shower room can not automatically sense a blowing shower, to check whether the wind shower room sensing system is working properly, whether the installation is correct, if the light sense two sides are opposite and the light sense is normal, it may be that the door of the wind shower room is not completely closed, which leads to the wind can not be blown shower. The sealing and cleanliness of the door need to be checked to ensure that it can be closed completely.

More serious faults, such as a power failure in the air shower room or serious damage inside the machine, usually require contacting the manufacturer or a skilled maintenance professional for repair and replacement as soon as possible.
 
Keeping your air shower room functioning properly is key to the cleanliness and safety of your cleanroom. Mastering some common troubleshooting methods can effectively reduce the failure rate and extend the service life of the air shower room. At the same time, the need for regular inspection and maintenance of the air shower room, early detection, and problem-solving, to ensure that the air shower room is always in the best state.