I. Introduction to the structure of the air shower room
1、air shower room by the box, stainless steel door, high-efficiency filter equipment, fan, power distribution box and nozzle, and several other components;
2、the bottom plate of the air shower room is generally bent and welded by the steel plate, and the surface is white baking paint spraying;
3、the box body is made of high-quality cold-rolled steel plate material, after electrostatic spraying treatment, beautiful and generous, but also very easy to clean.

II. Product characteristics of the air shower room
1、the use of more in line with the principle of operation of the equipment rounded corner design;
2、The purification level of the equipment has reached the static thousand level;
3、The filtration efficiency of the equipment is 99.99%;
4、Adopt a one-way channel design, people or goods from the non-clean area to enter, after closing the door infrared induction automatic blowing shower;
5、The electronic interlocking door is made of stainless steel, the window is transparent and the inner bottom plate is full stainless steel;
6、Adopt automatic infrared induction blowing shower, double doors will automatically lock when blowing shower;
7、equipped with stainless steel multi-angle adjustable nozzle and large air volume of low-noise fan; 8, set up with noise reduction, silent system, smooth operation, no noise.

III. the use of air shower room specifications.
1、into which the staff should be outside the changing room to take off their outer clothing, in addition to watches, mobile phones, accessories, and other items;
2、when entering the inner changing room should wear special purification clothes, hats, masks, gloves, etc.;
3、after entering the air shower room, the person should immediately close the outer door and start automatically for 1 minute;
4、after the end of the wind shower, should be promptly into the environment of the barrier.

IV. Management norms of the air shower room.
1、the air shower room should be managed by a professional responsible person, and to do regular replacement of the primary filter material;
2、under normal circumstances, every 2 years to replace the air shower room high-efficiency filter material;
3、In the air shower room the internal and external doors should be lightly closed and lightly opened;
4、if the air shower room fails, should promptly notify the professional maintenance personnel to repair it.