German French Italian Portuguese Japanese Korrean Russian
Home

News

Problems and solutions for activated carbon filter failures

Problems and solutions for activated carbon filter failures

I, the problem of activated carbon filter failure

1、The transportation of the equipment is not in place to prevent vibration, bruises, and other phenomena.

2, in the transportation and installation process of rain, waterproof work is not tight, and moisture problems.

3、The verticality of the equipment does not meet the requirements during installation and is not firmly fixed.

4, the insulation facilities of the equipment are not enough, and the filter media of the filtration equipment is damp.

5, the filtration speed of the equipment is too low, making the back-blowing airflow insufficient.

6, equipment leakage problems, so the differential pressure can not reach the average standard.

7, the operation control method has problems, especially the lifting pressure being too fast, easy to lead to the instantaneous pressure difference being too large.

II, the solution to the problem of failure

To eliminate the above problems, we need to do a good job of preventive measures, you can connect 1 security cartridge at the flange of each cartridge outlet port, and the lower cartridge filtered gas can be released through the micro-pores in the security cartridge.
As the security cartridge increases the resistance of back-blowing to a certain extent, we need to appropriately increase the pressure of back-blowing gas and increase the volume of gas to balance, so that there is no problem.