      High-efficiency air supply outlet is a more ideal terminal filtration device, suitable for thousands, ten thousand, one hundred thousand class purification air-conditioning systems. More widely used in health, electronics, chemical, pharmaceutical, and other industries of purification. In the installation of the time to have a compliant environment space, at the same time before the installation of several precautions you should also understand, placed in the installation of the location of the clean room will have a great impact on the degree of purification. This explanation is a high-efficiency air supply installed and placed in the following ways and means:
      1, high-efficiency air supply outlet and air supply outlet size issues must be able to meet the design development requirements. It should be cleaned before installation.
       2, in the clean use of modern indoor environmental design for installation and replacement of a high-efficiency air supply outlet of the air supply, the air outlet flap and the ceiling plate management system between the seam staff should be added gasket.
       3, in the technical mezzanine installation and replacement of air outlets. Short ducts should be buried with the civil structure before installation. If there is a crack between the short duct and the ceiling, it must be plugged.
       4. Air outlets shall not be installed if the surface coating is damaged. The air outlet should be connected to the duct immediately after installation, and the open end should be sealed with plastic film and tape.
       5, before installation, the clean room must be analyzed with a comprehensive cleaning, wiping, purification, and air conditioning control of the interior if there is dust accumulation, should be cleaned and wiped again, to achieve such a clean production with the development of the ability to meet the requirements. If the air supply outlet is installed in the mezzanine or ceiling, the mezzanine or ceiling should be thoroughly cleaned and wiped clean.
       6, a clean room and clean air conditioning control system to meet the requirements of the development of a clean, clean air conditioning system must be designed for trial operation. After continuous operation for more than 12 hours, immediately re-clean the room and install a high-efficiency air supply outlet.
       7, transport and storage should be carried out according to the instructions of the design marking. During transport, care should be taken to prevent severe vibration and collision.
       8, The frame for installing the equipment should be smooth. The permissible deviation of flatness of one frame for each high-efficiency filter installation is not more than 1mm.
       9, air supply and frame for a sealing system using different sealing gaskets, self-adhesive, negative pressure sealing, liquid tank sealing, double ring sealing, and other methods, packing material surface, filter frame structure surface, frame through the surface and the liquid tank must be constantly wiped clean.