Maintenance and common faults in air showers

Maintenance and common faults in air showers

1. When the air shower is used for a period of time, if the wind speed is very low, the filter of the air shower room should be checked immediately to see if it can accumulate too much dust, such as a new replacement for the filter. Usually 1-6 months it is necessary to exchange once, high efficiency filter is usually 6-12 months exchange once.
2. If the air shower room can not automatically induction blowing shower, check the light sensing system in the lower right corner of the box in the air shower room, see whether the light sensing equipment can be correct.
If the emergency stop key is red, it means that the air shower room will not blow the shower, only need to press the emergency stop key from the beginning can work normally.
3. When the air shower room does not work, the primary check a poor shower door outside the box of the emergency switch can be blocked, if blocked, with a hand quietly a press, to the right side of the rotation of the release can be.
4. air shower room fan reverses or perhaps air shower room wind speed is very small, it is necessary to check whether the 380V three-phase four-wire line can be connected backwards. If the line source of the wind shower room is reversed, the lighter will cause the wind shower room fan does not work or reverse the wind shower room wind speed is reduced, the heavier will burn the entire wind shower room circuit board.

 

Maintenance methods for air showers

1、regularly use the instrument to determine the technical indicators of the equipment, such as does not meet the requirements of technical parameters should be dealt with in a timely manner.
2、According to the actual use, the filter media in the primary air filter should be removed and cleaned regularly.
3、when the wind speed is found to become small should first check whether the surface of the primary air filter is black, if black, it means that the pre-filter allows more dust, increased resistance, that is, the non-woven fabric in the primary air filter should be removed for cleaning or be replaced.
4、When the non-woven fabric is replaced or cleaned, it still cannot improve the air speed, it means that the high efficiency air filter is blocked and the resistance increases, so the high efficiency air filter should be replaced.
5、When replacing the high efficiency filter, remove the spray ball plate, take out the high efficiency filter and replace the new high efficiency air filter according to the specification of the original high efficiency filter. The arrow mark on the high efficiency filter should be confirmed during installation, and the arrow should point to the direction of airflow. And ensure good sealing to prevent leakage.
6、After the replacement of the high efficiency filter, it should be confirmed that there is no leakage in the frame and tested with a dust particle counter, and only after reaching the technical index can the filter work normally.
7、Regularly overhaul the electrical wiring, if there is a fault, you can refer to the electrical schematic diagram for maintenance.
8、Regularly enclose the door so that the electronic lock is aligned with its lock hole to avoid the locking pin from jamming.
9、The use temperature shall not exceed 50℃, and the use of open flame is strictly prohibited.

Common faults in air shower rooms

1.Power switch, there are usually four places in the air shower room where the power can be cut off:
      the power switch of the outer cabinet of the air shower room.
      the control panel of the inner box of the air shower room.
      air shower room on both sides of the outer box (here the power switch can prevent emergency cut off power, effectively improve our personal safety). When the        power indicator does not work, do not prevent re-check the above four wind shower room power supply.
2.When the air shower room fan does not work, the first time to check whether the emergency switch outside the box of the air shower room is cut off, such as to determine the cut off, with a light hand, to the right side of the rotation of the release can be.
3.Air shower room fan reverses or air shower room wind speed is very small, please be sure to check whether the 380V three-phase four-wire line is reversed, the general factory installation will have a dedicated electrician to connect the line;
such as reversing the line source of the air shower room, the lighter will cause the air shower room fan does not work or reverses the air shower room wind speed is reduced, the heavier will burn the entire air shower room circuit board; we do not lightly to replace the wiring.
4.Air shower room does not blow shower, in addition to the above three points, but also need to check whether the emergency stop key inside the air shower room box pressed, such as the emergency stop key by colour, the air shower room will not blow shower;
to press the emergency stop key again can work normally.
5.Air shower room can not automatically induction blowing shower, check the air shower room in the lower right corner of the box of light-sensing system, see whether the light-sensing device is installed correctly, such as light-sensing two sides are relative and light-sensing normal, then can automatically induction blowing shower.
6.When the wind speed of the air shower room is very low for a period of time, please check whether the primary and high efficiency filters of the air shower room have accumulated too much dust, if so, please replace the filters.
(The primary filter of the air shower room is generally replaced within 1-6 months, and the high efficiency filter of the air shower room is generally replaced within 6-12 months)