How to arrange the nozzles of the vertical flow air shower room?

How to arrange the nozzles of the vertical flow air shower room?

The high-pressure gas generated by the centrifugal fan in the vertical flow air shower room is filtered through the medium-efficiency filter and the high-efficiency air supply port to produce a fast clean cyclone that is ejected from the stainless steel nozzle, and the air is supplied from the bottom to form a vertical one-way bottom air supply cycle. The nozzle is set at the top of the air shower room.

At present, the general air shower room has nozzles on both sides of the shower area, with 6 nozzles on each side of each connection. For example, a two-person double-blowing air shower room. Due to structural limitations, the relative height of the nozzles on both sides is not less than 1m from the ground. In addition, most of the nozzles used in the air shower room at present are adjustable, and this design has historical factors.

When the air shower room was first built, there were only azimuthally movable nozzles, but because the nozzles were set at a relatively high position in the internal structure of the air shower room and the number was small, they only had a shower effect on the upper body during use. Therefore, the designer changed the azimuthally movable nozzles to azimuthally adjustable nozzles, and the direction of the nozzles can also be adjusted according to the specific application situation so that more parts of the body surface can be showered. With the advent of adjustable nozzles, another problem also exists.

Because the shower air has a very high speed, when it blows on the surface of the body, some people always feel uncomfortable and do not want to be showered. After entering the air shower room, they always turn the nozzle direction to face the entrance door to avoid being showered.

The vertical air shower room is a necessary passage for personnel to enter the clean room. To reduce the dust generated by personnel entering and leaving the clean room, a fully functional airlock is installed at the entrance of the clean room to reduce air pollution. When the staff passes through the air shower room, the polluted dust particles are ejected by the high-efficiency filtration and high-efficiency filtration. The dust particles are filtered out by the primary filtration and high-efficiency filtration.

Working contents of vertical direct current air shower room:

1. Double doors are interlocked before personnel enter the air shower room. Personnel need to enter the air shower room from the first door and open and close when going out

2. Personnel enter the air shower room and automatically exit when entering

3. Voice broadcast, infrared induction intelligent induction shower, double doors open and close when showering

4. After showering, personnel need to get rid of the door from the outside, open and close when entering and automatically exit when going out.