German French Italian Portuguese Japanese Korrean Russian
Home

News

Automatic air shower door configuration and its operating characteristics

Automatic air shower door configuration and its operating characteristics

The air shower door is a kind of local purification equipment with strong versatility, which is used to remove dust on the surface of people or objects by the fan with the help of air shower nozzles when the staff enters the clean area. Automatic air shower door configuration and its operating characteristics.

Automatic air shower door configuration: automatic air shower door main material by a clean and dust-free cold rolled steel composition, three hundred and sixty degrees adjustable stainless steel nozzles durable and durable, strengthen the design of the aluminum door frame with optional toughened glass doors and windows, more durable and durable, the air shower door is equipped with indicators, air shower door chassis material for stainless steel, clean and tidy easy to clean. Finishing release.

Automatic air shower door operating characteristics:
1. The air shower door shows red light to remind personnel not to open the door, while the green light indicates that you can enter.
2. According to the setting of the air shower door operation procedure, the indicator light will give the staff the indication of the air shower process by red or green light.
3. In addition to setting the operation mode of the air shower door, the user can also independently set the self-cleaning exhaust timing, air shower time, and dormant waiting time according to the actual situation.
4. The basic factory setting of the self-cleaning exhaust timer of the air shower door is ten seconds, and the user can set it between zero and three minutes. The air shower door will turn to a sleep state when there is no one to use it. In the dormant situation, the fan speed is in the maintenance range of clean low speed, to reduce energy consumption.
5. The overhead light of the shower door is switched off to save energy. The time required from the working state to sleep state is the hibernation waiting time. Sleep waiting time can be set between 5 seconds to 1 minute, the basic factory setting is ten seconds.
6. The electronic interlock system prevents the air shower door from being opened at the same time, which may cause airflow through the clean room. The air shower time can be set between five seconds and three minutes, and the basic factory setting is twelve seconds.