Air shower room maintenance and maintenance is immediately associated with the air shower room work efficiency and air shower room use period

1. Wind shower room installation accurate positioning. Do not casually move, rectify; if you need to change the move to find staff and manufacturers of specific guidance, move to review the road level again, to prevent the door frame deformation, endangering the normal work of the air shower room in all.
 
2. The location of the air shower room equipment and the natural environment should be excellent natural ventilation and dry.
 
3. Do not touch or apply all automatic switches under all normal working attitudes of the air shower room.
 
4. People or goods in the magnetic induction area, the switch in the acceptance of magnetic induction, before entering the blowing procedure flow.
 
5. Do not transport large objects from the air shower room to prevent damage to the surface and electrical control.
 
6. The control panel inside and outside of the air shower room should not be hit with hard blocks to prevent scratches.
 
7. Air shower room door is an electronic device interlock, when a door opens another door fully automatic lock, do not force the power switch on two doors, or switch operation, and do not force the power switch on all a door.
 
8. Once the blowing shower room is set up, do not adjust it casually.
 
9. The air shower room needs to choose the responsible person management method, a quarter on time to remove and replace the filter.
 
10. The average value of every 2 years to remove and replace the high-efficiency filter of the air shower room.
 
11. The air shower room should open and close the inner and outer doors of the air shower room lightly.
 
12. When the air shower room produces common faults, should be immediately reported to the maintenance personnel maintenance. General conditions prohibit the start of the manual key.
 
The following are the air shower room maintenance-related matters.
 
1. Air shower room repair, maintenance, and repair of machinery and equipment be sure to learn the actual operation of the staff training.
 
2. Air shower room power supply circuit is installed in the door to the upper side of the box, open the control panel anti-theft locks can be accessed to dismantle the circuit boards, and maintenance must be turned off when the switch is powered.
 
3. High-efficiency filter is installed in the middle section of the main box (behind the nozzle plate), open the nozzle control panel can be removed from the high-efficiency filter.
 
4. Installation of the door closer itself, the speed control valve towards the door hinge, and closing the door to let the door in the effectiveness of the door closer to turn off at will, do not add more external force, otherwise it will destroy the door closer wash.
 
5. Air shower room centrifugal fan is installed in the air shower room box side directly below, dismantle the air supply over consideration.
 
6. Door magnetic switch and electronic device lock (double door self-locking interlock) are installed in the air shower room door frame in the middle of the part, open the face of the electronic control lock screws can be repaired and maintained.
 
7. Intermediate effect filter (for air supply) is installed in the air shower room box body directly below the two sides (i.e., after the hole plate), open the hole plate can be removed and replaced or cleared.